Skip to main content
GET
/
context
/
diagram
/
detect
/
{jobId}
Retrieve engineering diagram detect results
curl --request GET \
  --url https://{cluster}.cognitedata.com/api/v1/projects/{project}/context/diagram/detect/{jobId} \
  --header 'Authorization: Bearer <token>'
{
  "jobId": 123,
  "status": "Queued",
  "createdTime": 1730204346000,
  "startTime": 1730204346000,
  "statusTime": 1730204346000,
  "items": [
    {
      "fileId": 1234,
      "annotations": [
        {
          "text": "21-PT-1019",
          "region": {
            "shape": "rectangle",
            "vertices": [
              {
                "x": 0.58,
                "y": 0.12
              }
            ],
            "page": 1
          },
          "confidence": 0.5,
          "entities": [
            {
              "userDefinedField": "21PT1017",
              "ignoredField": "AA11"
            },
            {
              "userDefinedField": [
                "21PT1017-A",
                "21PT1017-B"
              ]
            }
          ]
        }
      ],
      "fileExternalId": "1234",
      "fileInstanceId": {
        "space": "space",
        "externalId": "externalId"
      }
    }
  ],
  "errorMessage": null,
  "searchField": "userDefinedField",
  "partialMatch": false,
  "minTokens": 2
}

Authorizations

Authorization
string
header
required

Access token issued by the CDF project's configured identity provider. Access token must be an OpenID Connect token, and the project must be configured to accept OpenID Connect tokens. Use a header key of 'Authorization' with a value of 'Bearer $accesstoken'. The token can be obtained through any flow supported by the identity provider.

Path Parameters

jobId
integer<int64>
required

Contextualization job ID.

Example:

123

Response

Success

jobId
integer<int64>
required

Contextualization job ID.

Example:

123

status
enum<string>
required

The status of the job.

Available options:
Queued,
Running,
Completed,
Failed
createdTime
integer<int64>
required

The number of milliseconds since 00:00:00 Thursday, 1 January 1970, Coordinated Universal Time (UTC), minus leap seconds.

Required range: x >= 0
Example:

1730204346000

startTime
integer<int64>
required

The number of milliseconds since 00:00:00 Thursday, 1 January 1970, Coordinated Universal Time (UTC), minus leap seconds.

Required range: x >= 0
Example:

1730204346000

statusTime
integer<int64>
required

The number of milliseconds since 00:00:00 Thursday, 1 January 1970, Coordinated Universal Time (UTC), minus leap seconds.

Required range: x >= 0
Example:

1730204346000

items
object[]

An array of detected results, returned when the job finished or failed partially.

errorMessage
string

If the job failed, some more information about the error cause.

Example:

null

searchField
string
default:name

This field determines the string to search for and to identify object entities.

Example:

"userDefinedField"

partialMatch
boolean
default:false

Allow partial (fuzzy) matching of entities in the engineering diagrams. Creates a match only when it is possible to do so unambiguously.

minTokens
integer
default:2

Each detected item must match the detected entity on at least this number of tokens. A token is a substring of consecutive letters or digits.

Last modified on April 23, 2026