Pular para o conteúdo principal

Parse model revisions

Beta

The features described in this section are currently in beta testing and are subject to change.

The GAP connector extracts the information model from GAP simulator model revisions. This feature parses the flowsheet hierarchy of GAP simulator model revisions, including functional blocks, such as process equipment, block properties, such as operating parameters, physical properties and configuration settings, connections between blocks, and graphical information for visualization processes.

The connector stores the parsed information in Cognite Data Fusion (CDF) alongside the associated simulator model revision.

Prerequisites

Model parsing automatically activates when:

  • A valid modelparsing.config.yml file exists in the connector's configuration directory.

  • A new simulator model revision is created or an existing model revision is reparsed.

  • The GAP model contains a single flowsheet.

Configure parsing

You configure the model parsing in a separate YAML file (modelparsing.config.yml) that defines which properties to extract from different equipment types.

Configuration file structure

# Common properties extracted from all equipment types
common-properties:
- name: OilRate
value-type: DOUBLE
unit:
quantity: Liquid Rate
description: Oil rate from the network solver.
address-suffix: .SolverResults[0].OilRate
- name: WaterRate
value-type: DOUBLE
unit:
quantity: Liquid Rate
description: Water rate from the network solver.
address-suffix: .SolverResults[0].WaterRate

# Equipment-specific properties
equipment-properties:
- equipment: well
properties:
- name: WellModel
value-type: STRING
description: Type of well model used.
address-suffix: .WellModel
- name: TypeWell
value-type: STRING
description: Type of well.
address-suffix: .TypeWell
- equipment: pipe
properties:
- name: PipeModel
value-type: STRING
description: Type of pipeline model used.
address-suffix: .PipeModel
- name: PipeCorr
value-type: STRING
description: Type of pipeline correlation used.
address-suffix: .PIPECORR

Property configuration parameters

ParameterDescriptionRequired
nameThe display name for the property.Yes
value-typeThe data type of the property. Supported values: STRING, DOUBLE, STRING_ARRAY, DOUBLE_ARRAY.Yes
address-suffixThe GAP address suffix to append to the equipment address to retrieve the property value.Yes
unit.quantityThe unit quantity associated with the property. Only relevant for numeric properties.No
descriptionA brief description of the property for documentation purposes.No

Extract information

This is how the GAP connector extracts information from simulator model revisions:

  1. Loads the model: When a simulator model revision is validated, the connector loads the GAP model.

  2. Discovers equipment: The parser queries GAP to discover all equipment types and instances in the model.

  3. Extracts properties: For each equipment instance, the parser:

    • Extracts common properties defined in the configuration.

    • Extracts equipment-specific properties based on the equipment type.

    • Retrieves unit information for numeric properties.

  4. Generates edges: The parser analyzes equipment connections to generate edges representing material flows

  5. Stores the information model: The complete information model is stored in CDF and associated with the simulator model revision.

Access parsed information

When a simulator model revision has been parsed, use the simulator model revision endpoints to fetch the associated flowsheet data.

Property extraction errors

During model parsing, the connector automatically skips any property where it fails to extract data to continue parsing. For example:

Invalid address

If the address-suffix contains a typo, for instance, .SolverResults[0].OliuRate instead of .SolverResults[0].OilRate, the property is skipped.

Incorrect unit quantity

If the specified unit.quantity doesn't match the property type, for instance, using Temperature for a pressure value, the property extraction fails and is skipped.

Wrong value type

If the value-type doesn't match the actual data type, for instance, specifying DOUBLE for a string property, the property is skipped and the connector logs details about the failed property extraction, continues processing remaining properties, and excludes the failed property from the final information model.

Limitations and considerations

  • Only GAP models with a single flowsheet are supported. The connector skips parsing for models with multiple flowsheets.

  • Model parsing requires a valid configuration file.

  • Model parsing adds processing time during model validation. The impact depends on model complexity.

  • Not all properties may be available for all equipment types. Missing properties are logged and skipped.

  • Unit information is retrieved when available, but may be missing for some properties.